PVC, PE, EVA and PUR air conditioning hoses, ventilation hoses, welding smoke hoses | AIRDUC® PE 362 FOOD polyethylene foodstuff hose and pharmaceutical hose, medium weight (-35°C to 80°C)

PVC, PE, EVA and PUR air conditioning hoses, ventilation hoses, welding smoke hoses
PROTAPE® PVC 310 PVC hose, lightweight -20°C to 70°C
AIRDUC® PVC 341 PVC hose, medium-heavy -20°C to 70°C
AIRDUC® PVC 345 PVC hose, heavy -20°C to 70°C
PROTAPE® PVC 371 PVC ventilation hose (up to +110°C) -10°C to 80°C
PROTAPE® PVC 371 HT PVC ventilation hose, (up to +120°C) -10°C to 110°C
PROTAPE® PUR 370 Polyurethane ventilation hose, (up to +125°C)
CP PVC 465 PVC clamping profile hose, (to +110°C) -10°C to 80°C
CP PVC 465 EC PVC clamping profile hose, (up to +110°C)
CP PVC 466 HT PVC clamping profile hose, (up to +120°C)
CP HiTex 467 WELDING Clamping profile hose for flying sparks and welding spatter, (up to +280°C)
CP PE 457 Polyethylene clamping profile hose (-35°C to 80°C)
CP PE 457 EC Electrically conductive polyethylene clamping profile hose (-35°C to 80°C)
PROTAPE® PE 322 EC Electrically conductive polyethylene hose, lightweight (-35°C to 80°C)
AIRDUC® PE 362 FOOD polyethylene foodstuff hose and pharmaceutical hose, medium weight (-35°C to 80°C)
AIRDUC® PE 362 EC Electrically conductive polyethylene hose, medium weight (-35°C to 80°C)
SuperFlex PVC 372 Highly flexible PVC hose, lightweight 0°C to 85°C
EVA 373 vacuum cleaner hose -45°C to 65°C
EVA 373 AS vacuum cleaner hose, antistatic <10¹¹ Ohm -25°C to 65°C
EVA 373 EC vacuum cleaner hose, electrically conductive <10⁶ Ohm -25°C to 65°C

AIRDUC® PE 362 FOOD polyethylene foodstuff hose and pharmaceutical hose with medium weight design.

The medium-weight polyethylene hose PROTAPE® PE 362 FOOD with an extremely good chemical resistance is odourless and free of smudges, the wall is also food-safe. format on this page. The hose finder and information about dimensions, assembly, stock, prices and delivery times can be found in detail in our online shop. For further questions please contact us!

Item no.
 
Label
 
Internal ∅
inch / mm
External ∅
mm
Excess pressure
bar
Negative pressure
bar
Bending radius
mm
Bearing length
Meter
Weight
kg
Stock
 
Price
?
Graduated price
 
quantity
 
 
 
 
 

Frequently asked questions (FAQ)

This hose can be used in a clean room and can be used without hesitation for foodstuffs such as rice, sugar, powdered milk, coffee, tea, cereals and other dry food. Frozen food can also be transported

This is a suitable hose for conveying and transporting pharmaceutical products. Due to their food-safe walls and other important properties, these hoses are suitable for use in the pharmaceutical industry. This includes, for example, use in vacuum conveyors, suction conveyors, dosing systems and tablet presses.

All listed products with the marking FOOD are food safe, tasteless and odourless.

Yes, all the specified hoses are flow-optimised due to their geometry and the smooth inner wall.

Polyethylene hoses of the PE FOOD series, which are manufactured from special and particularly high-quality raw materials, are excellently suited for many applications in the food industry. The following hose types belong to this product series: AIRDUC? PE 362 FOOD Among other things, the material used for the hose wall has the following properties: FDA conformity (Food and Drug Administration of the USA): The material complies with the U.S. Food and Drug Administration as a food contact substance (FCN), result of a premarket notification dated 28.09.2007 under FCN741. This notification permits the use of this material with all types of food under conditions A to H, described in Table 2 of FDA CFSAN of Food Additivs Safety, April 2006, "Definitions of Food Types and Conditions of Use for Food Contact Substances. In the production of the above mentioned polyolefin copolymers, only auxiliary materials are used that meet the requirements and limits of 21 CFR 177.1520(c), item 3.1 or 3.2. EU regulation 10/2011: The starting materials used are listed in Regulation 10/2011. The raw materials used do not contain dual use additives (Note: The above mentioned guidelines for food contact, which are based on EU directives, sometimes lead to limitations of the residual content of individual plastic components. We would like to draw your attention to the fact that EU Regulation 10/2011, which applies to all EU member states, sets a limit for migration from plastic products in the food sector. Even if, as in this case, there is an official confirmation from the manufacturer, in accordance with the EU regulation 10/2011, these measurements should be carried out by the user on the end product, in contact with the corresponding food or food simulating substances. Time and temperatures should be chosen in such a way that they correspond to the actual conditions in normal use of the articles, according to the rule of the EU regulation 10/2011. It is the responsibility of the user to ensure that the article is suitable for the intended use.

Vibraplast AG offers its customers an assembly service of connecting parts. For a hose with assembled fittings an additional delivery time of 3 working days must be expected.?

TECHNICAL TERMS AND DEFINITIONS Abrasion Undesirable change of the surface due to loosening of small particles as a result of mechanical stress. Also generally known as wear. The abrasion is determined according to DIN 53516. Here, a specimen is guided with a certain contact pressure on a rotating roller covered with a test emery sheet. The total friction path is approx. 40 m. The loss in mass caused by abrasive wear is measured, taking into account the density of the test specimen and the attack of the emery sheet. The information is given as volume loss in mm?. Additives All components in a plastic formulation which are not polymers or their precursors and which are only added in relatively small quantities (UV stabilizers, flame retardants, conductive carbon black, etc.) Aging The totality of all chemical and physical processes irreversibly taking place in a material over time. This usually leads to a deterioration of the service properties. Heat, light, high-energy radiation, chemicals, weather, oxygen (ozone) are frequent causes of ageing. The aging condition, mostly surface attack, is monitored by changes in material properties such as toughness, turbidity, molecular weight, etc. Bending radius Smallest permissible radius when laying a hose line. The bending radius is given in mm and always refers to the inside of the hose bend. Compression set The determination of the compression set DVR [%] according to DIN 53517 is a creep test over 24 hours at 70 ?C and 72 hours at room temperature with constant deformation. The permanent deformation is measured after the specimen is unloaded again. Elasticity Means the ability of a material to reshape after removal of an externally applied mechanical stress. Elastomers Designation for wide-meshed, cross-linked, macromolecular substances which can be stretched by at least twice their original length by the application of a slight force at room and higher temperatures and which, once the force has been removed, return rapidly and practically completely to their original form. Flame retardants Are plastic additives which reduce the flammability and combustibility of plastics. Flame retardants can intervene in the combustion mechanism either physically by cooling, coating and diluting or chemically by reaction in the gas phase (elimination of the energy-rich radicals supporting combustion) or in the solid phase (formation of a protective coal or ash layer). Flexibility Force required to achieve the minimum bending radius (the greater the force required, the less flexibility). Flow / Creep The delayed but still reversible deformation of a viscoelastic material under constant load is called creep. The irreversible deformation occurring at higher loads is called flow (in cold state). The flow process leads to failure of the component under unchanged load. Gas permeability Passage of a gas through a test sample. This takes place in three steps: Dissolving the gas in the sample. Diffusion of the dissolved gas through the sample. ? Evaporation of the gas from the sample. The permeation coefficient is a material constant which indicates which volume of gas passes through a test specimen of known area and thickness at a given partial pressure difference in a given time. It depends on the temperature and is determined according to DIN 53 536. Halogens The elements fluorine (F), chlorine (Cl), bromine (Br) and iodine (I) form the group of halogens. Hardness Hardness is the resistance of a material to the penetration of a body of a certain shape and defined spring force. The penetration depth of the test body is a measure of hardness. The hardness of elastomers is determined according to Shore A or Shore D in accordance with DIN 53505. It is given as a whole number from 0 to 100 and the letters A and D. The larger the number, the higher the hardness. Hydrolysis resistance Hydrolysis = irreversible splitting of the polyester chains in ester polyurethanes. It is caused by prolonged storage in warm water, saturated steam, tropical climate (moisture in combination with heat), aggressive chemicals or aggressive wood dusts. The consequence of hydrolysis is a decrease in mechanical strength properties. Ether polyurethanes are resistant to hydrolysis. Microbe resistance Ester polyurethanes can be destroyed by long-term contact with earth-like substances or heavy contamination under conditions favourable to microbes, as the enzymes released by the organisms damage the chemical bonds. Under very unfavourable conditions, initial damage occurred after 8-24 weeks. This time can be delayed by adding toxic fungicides, but later on, by leaching and leaching of the additive, the value may fall below the limit required for protection. It is of the utmost concern that the often toxic fungicides inevitably migrate to the surface and come into contact with the user or conveyed material. Such solutions do not meet our quality level and are therefore not part of our product range. Our hoses made of ether polyurethane are permanently not attacked by microbes and are the clearly better solution here. Specific volume resistance According to TRGS 727 the volume resistivity RGES = R?A/S [??m] must be determined. Where R is the measured resistance, A is the surface area of the electrode and S is the thickness of the reed between the plastic and the wire. A piece of hose 100 mm long with a cylindrical electrode inserted on one side is measured, with the counter electrode forming the steel wire helix. The volume resistivity determined thereby must be RGES < 2.5 x 1018 Ohm. Surface resistivity The surface resistance (Ro) indicates the insulating capacity of the insulating material surface. Ro is reduced in plastics by the formation of a water film which is created by the action of hydrophilic groups (-COOH, -NH2, -OH), plasticizers and organic fillers. Ro is determined at a test voltage of 1 kV between two electrodes (spring-loaded metal blades) located at a distance of 10 mm. Ro is given either in ohms or as a comparative figure, e.g. 10 = Ro < 10 or comparative figure 6; 10 = Ro < 10 or comparative figure 11. Permeation The passage of a gas through a sample is called permeation. It takes place in three steps: Dissolving the gas in the sample Diffusion of the dissolved gas through the sample Evaporation of the gas from the sample The permeation coefficient Q in m?/(s * Pa) is a material constant which indicates the gas volume ? passes through a test specimen of known area and thickness at a given partial pressure difference in a given time. It depends on the temperature and is determined according to DIN 53536. Swelling Absorption of liquid and gaseous substances into solids without a chemical reaction taking place between them. The consequences are an increase in volume and weight combined with a corresponding decrease in mechanical values. After evaporation of the penetrated substance and the associated decrease in swelling, the original properties of the product are almost restored. The swelling is therefore a reversible process. Peak compressive strength Resistance to compression of suction and discharge hoses by external load applied at the apex. Water vapour permeability It is characterised by the amount of water vapour that passes through 1 m? of sample surface in 24 hours under defined conditions and is approximately inversely proportional to the sample thickness. The water vapour permeability WDD in g/(m?*d) of a plastic is determined according to DIN 53122 sheet 1. Tear resistance Tear propagation resistance is the resistance that a notched test piece offers to tear propagation. The test is carried out in accordance with DIN 53515 on angle specimens which are provided with a notch on one side. UV radiation Depending on the duration and intensity, plastics can be chemically degraded by the action of UV radiation (ageing). Polyurethanes generally have a good UV resistance. In the course of time, the material turns yellow, which does not automatically cause a decrease in the mechanical properties. With the help of UV stabilizers and/or color pigmentation a certain stabilization can be achieved. We offer special hose solutions for increased and strong UV- exposure. Please contact us in such cases.

AIRDUC? (incl. TIMBERDUC? 533 - 534) Vibraplast AIRDUC? profile hoses have a spring steel wire firmly cast in the wall and are spirally welded. They are very smooth on the inside, axially very stiff but still flexible and compared to comparable rubber hoses they have a low weight. This increases customer benefit, creates added value and often saves costs. Talk to us! Welding 1 : material-locking and safe connection gas- and liquid-tight possibility of customer-specific partial and full colouring long weld seam for more process and operational safety Extruded profile hose with high flow rate 2 : high Schlauchinnengl?tte? less depositing of the F?rdergutes? gentle transport of the conveyed material ?flow-optimised Profilform? low Druckverluste? reduction of Gebl?seleistung? lower operating costs reinforced wall at the primary wear points Optimized design 3 : High axial stiffness extremely flexible even wrinkling Steel wire 4 : spring steel wire firmly cast in the wall no softening of the reinforcement at high temperatures (in contrast to all-plastic hoses) Dissipative through earthing of the steel wire

By using this website, you consent to the use of cookies and our privacy policy. Privacy policy agree.
If you have any questions, please contact info@vibraplast.ch

This content is reloaded